SeqStudio Flex genetic analyzers: consumables and service

Capillary arrays for the SeqStudio 8 Flex and SeqStudio 24 Flex, the polymer pouches and buffer containers they share with the 3500 series, and service with online array regeneration.

Updated

Key facts

  • Two models: the SeqStudio 8 Flex with 8 capillaries and the SeqStudio 24 Flex with 24.
  • Arrays in 36 cm and 50 cm: A49104 and A49106 for 8 capillaries, A49105 and A49107 for 24.
  • SeqStudio Flex arrays are specified for 160 injections and are not interchangeable with 3500 arrays.
  • The polymer pouches, buffer containers and conditioning reagent are the same products as for the 3500.

Capillary arrays

Each array fits only its own model: 24-capillary arrays run only on the SeqStudio 24 Flex. The arrays carry RFID tags that record the lot, part number, expiry date and use, and the software reminds you when an array is expired or overused.

Capillary arrays for the SeqStudio Flex series
ProductInstrumentCapillariesArray lengthOEM part no. (reference)Price
8-capillary array, 36 cmSeqStudio Flex836 cmA49104Ask for price
8-capillary array, 50 cmSeqStudio Flex850 cmA49106Ask for price
24-capillary array, 36 cmSeqStudio Flex2436 cmA49105Ask for price
24-capillary array, 50 cmSeqStudio Flex2450 cmA49107Ask for price

Swipe sideways to see all columns.

OEM part numbers are shown for cross-reference only, so you can match what your instrument uses today.

Polymer and buffers shared with the 3500

The manufacturer labels its POP polymer pouches, anode and cathode buffer containers and conditioning reagent “for 3500/SeqStudio Flex”, so one stock serves both instrument families. The 50 cm arrays are optimized for POP-7, POP-6 and POP-4 run modules.

POP polymer pouches for the 3500 and SeqStudio Flex
ProductPouch sizeTypical useForOEM part no. (reference)Price
POP-7 polymer pouch96 samplesSequencing and fragment analysis3500 / 3500xL / SeqStudio FlexA26073Ask for price
POP-7 polymer pouch384 samplesSequencing and fragment analysis3500 / 3500xL / SeqStudio Flex4393708Ask for price
POP-7 polymer pouch960 samplesSequencing and fragment analysis3500 / 3500xL / SeqStudio Flex4393714Ask for price
POP-6 polymer pouch96 samplesHigh-resolution sequencing3500 / 3500xL / SeqStudio FlexA26071Ask for price
POP-6 polymer pouch384 samplesHigh-resolution sequencing3500 / 3500xL / SeqStudio Flex4393717Ask for price
POP-6 polymer pouch960 samplesHigh-resolution sequencing3500 / 3500xL / SeqStudio Flex4393712Ask for price
POP-4 polymer pouch96 samplesHuman identification (HID) and fragment analysis3500 / 3500xL / SeqStudio FlexA26070Ask for price
POP-4 polymer pouch384 samplesHuman identification (HID) and fragment analysis3500 / 3500xL / SeqStudio Flex4393715Ask for price
POP-4 polymer pouch960 samplesHuman identification (HID) and fragment analysis3500 / 3500xL / SeqStudio Flex4393710Ask for price

Swipe sideways to see all columns.

OEM part numbers are shown for cross-reference only, so you can match what your instrument uses today.

Buffer containers and reagents for the 3500 and SeqStudio Flex
ProductOn-instrument lifeForOEM part no. (reference)Price
Anode buffer container (ABC)Up to 14 days3500 / 3500xL / SeqStudio Flex4393927Ask for price
Cathode buffer container (CBC)Up to 14 days3500 / 3500xL / SeqStudio Flex4408256Ask for price
Conditioning reagent pouchSingle use3500 / 3500xL / SeqStudio Flex4393718Ask for price

Swipe sideways to see all columns.

OEM part numbers are shown for cross-reference only, so you can match what your instrument uses today.

Online regeneration of SeqStudio Flex arrays

When an array reaches its RFID limit but its capillaries still perform, you do not have to throw it away. We send a special washing liquid and a new RFID tag to replace the expired one; our engineer then regenerates the array with you in an online session, or your team follows our written protocol. The details are on the regenerated arrays page.

Maintenance and service

Daily checks, polymer and buffer changes and calibrations follow the same logic as on the 3500 series: keep the consumables within their limits, watch for bubbles and leaks, and recalibrate after every array change. We carry out preventive maintenance, calibrations and repairs on site or remotely, and send a written report. See genetic analyzer service.

Frequently asked questions

Can I use a 3500 capillary array on a SeqStudio Flex?

No. SeqStudio Flex arrays are not interchangeable with 3500 arrays. Use A49104 or A49106 on the SeqStudio 8 Flex and A49105 or A49107 on the SeqStudio 24 Flex.

Can I use 3500 POP-7 pouches on a SeqStudio Flex?

Yes. The POP-7, POP-6 and POP-4 pouches, such as A26073, are labelled for both the 3500 and the SeqStudio Flex.

Does a 24-capillary array fit the SeqStudio 8 Flex?

No. The 24-capillary arrays run only on the SeqStudio 24 Flex, and the 8-capillary arrays only on the SeqStudio 8 Flex.

How many injections does a SeqStudio Flex array last?

The arrays are specified for 160 injections or until the expiry date printed on them, whichever comes first.

Can SeqStudio Flex arrays be regenerated?

Yes, through online regeneration. We send the washing liquid and a new RFID tag, and the array is regenerated in your lab with our engineer online or with our protocol.

What is the difference between the SeqStudio and the SeqStudio Flex?

The SeqStudio is a 4-capillary benchtop analyzer with an all-in-one cartridge. The SeqStudio Flex has 8 or 24 capillaries and uses separate arrays, polymer pouches and buffer containers, like the 3500.